Leak Detector Went Off as Soon as I Stepped In The Room
On 8/28/2023 I started leak checking the evap and the leak detector went off as soon as I stepped in the room. I opened the main door as well as a couple glass doors to let it air out. I started another leak detection and found that there was a core cap missing and some […]
unit is run by dixell controller
On 7/27/2023 Arrived and found unit iced up…unit is run by Dixell controller I unplugged controller and compressor was still running come to find that someone was here prior to us and wired compressor direct and the controller was not working either …. I rewired everything as it should go and verified defrost was cycling […]
Three Blades on Fan Broken and Motor Damaged
On 7/18/2023 Arrived and removed product out of cooler…got to the fan coil motor and found the three blades on fan broken and motor damaged … I replaced motor and fan blade and turned on…unit left in operation running nice and quiet in Denton Texas. Near Fry St Denton, Texas 76201 Check out the Areas […]
Deep Cleaned it With Heavy Sanitizer
On 6/23/2023 System was extremely dirty so I took it apart and deep cleaned it with heavy sanitizer/descaler. I also noticed the water flow through the filter was reversed. Customer had extra length of hose some i was able to put it right. I put it back together and ran the machine through a descale […]
Replaced with High Pressure Switch
On 6/21/2023 I recovered all the refrigerant from both stages of the system. I removed the low-pressure switch that was placed on the high side and replaced with high pressure switch and wired it in correctly. I pulled a deep vacuum on both stages. And charged them with 407c in Dallas Texas. Near Lyndon B […]
reset the controller and went through set up
On 5/11/2023 reset the controller and went through set up, before it wouldn’t adjust over 28degrees so product was constantly freezing, I took out the parameters and reset up controller to be adjustable like the cooler next to it, it is now set to 35 and store can adjust accordingly from 40 degrees to 32, […]
shut off the fresh air damper
On 5/5/2023 found the fresh air damper opened manually to 100% I shut off the fresh air damper and opened the recirculation damper 100%, in doing so its now taking the cool air from inside the building and recirculating it instead of taking the 90 degree air from the roof and trying to cool that […]
Diagnosed and replace a bad condenser fan motor
On 2/20/2023 Diagnosed and replace a bad condenser fan motor in Carrollton Texas. Near Vantage Drive Carrollton, Texas 75006 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]