Walk-In Cooler Low Temp

Walk-In Cooler Low Temp. I found condenser fan blade hit a leg of power causing motor to run improperly which caused it to fail. I replaced motor, capacitor …
Kitchen HVAC Broken Pulley

Kitchen HVAC Broken Pulley. I found unit with a broken belt pully, and blown fuses, managed to pick fuses and pulley locally and replace them …
Installed New Freezer Door Handle

Installed New Freezer Door Handle. I installed door handle and readjusted push rod to fit in handle job is completed on 3/3/25 in Fort Worth Texas.
Replaced Section of Suction Line

Replaced Section of Suction Line on condenser. I resoldered joints on liquid line, replaced drier, then nitrogen and leak tested unit. No leaks …
Bar Cooler was not Cooling

Bar Cooler was not Cooling. I found overload faulty I installed a 1/2 hp 3 in 1 heart start to make repair and started unit up verified operation all ops normal
Cooler on Cook Line was Down

Cooler on Cook Line was Down. The toggle switch burned up and low-pressure control shorted. I installed new wiring as needed, toggle switch and pressure control
Reach-In Cooler Repair

Reach-In Cooler Repair. I replaced 2 evaporator fan motors and electronic board with control. I started unit up verified operation all ops normal at this time
Walk-In Cooler Not Working

Walk-In Cooler Not Working. I replaced burned condenser fuse and replaced contactor and unit came on and started cooling on 2/24/25 in Grand Prairie Texas.
Freezer Restriction on TXV Valve

Freezer Restriction on TXV Valve. I sweat off lines and replaced both components. I Added 4 pounds of 404A. Got to proper pressures and freezer began freezing
Pasta Cooker was Leaking Water

Pasta Cooker was Leaking Water. Drain hose had big hole on the side of it due to age. Water line was also leaking from joint. I replaced water hose and clamps