Ice Machine Not Working

Ice machine not working. Found loose wire to transformer, retightened and connected. Unit came on and is making ice on 9/26/24 in Ennis Texas. Near S Interstate 45 Service Rd, Ennis, TX 75119 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Open Case Cooler Condensate Pan Clogged

Open Case Cooler Condensate Pan Clogged, which was causing water to over flow. I unclogged drain line put unit back together verified drain and all ops normal at this time on 9/25/24 in Dallas Texas. Near Preston Rd Dallas, TX 75230 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ […]

Gelato Machine Not Working

Gelato machine not working, after diagnosis I found water was not on for the water condenser. I replaced the water inlet fittings and hose, started unit up verified operation all ops normal at this time on 9/24/24 in Dallas Texas. Near Preston Rd Dallas, TX 75230 Check out the Areas We Serve and jobs we […]

AC Condensation Line Not Properly Draining

AC condensation line not properly draining. I was able to properly insulate line and have it drain properly as well to make repair on 9/23/24in Anna Texas. Near Dale Evans Drive Italy, TX 76651 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Found Transformer tripped

Found transformer tripped. After resetting it, started unit up and noticed contactor chattering. After diagnosis units wiring has been altered on 24v side after making repair started unit up verified operation all ops normal at this time on 9/21/24 in Anna Texas. Near N US Hwy 75 Anna, TX 75409 Check out the Areas We […]

Found Drain Pan Full

Found drain pan full indicating secondary and primary drain lines were both clogged. Blew lines with nitro and watched pain drain properly on 9/19/24 in Frisco Texas. Near Ohio Drive Frisco, TX 75035 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Found Unit Frozen Over

Found unit frozen over, after thawing unit out found evaporator very dirty, also checked pressures and superheat. started unit up verified operation all ops normal at this time on 9/18/24 in Grand Prairie Texas. Near S Great SW Pkwy Grand Prairie, TX 75052 Check out the Areas We Serve and jobs we are doing by […]

Installed Mags, Caps, Diodes and Mag Thermostats

Installed Mags, Caps, Diodes and Mag Thermostats. After installation I started unit up and verified operation, all ops normal at this time on 9/17/24in Hillsboro Texas. Near Corsicana Highway Hillsboro, TX 76645 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Case Cooler Low on Freon

Case Cooler Low on Freon due to leaking packing nut on king valve and TXV wide open. Repaired leak, cleaned coil and charged unit with 6lbs of r449a and adjusted TXV to proper superheat on 9/16/24 in Hutchins Texas. Near I-45 Hutchins, TX 75141 Check out the Areas We Serve and jobs we are doing […]

Replaced Faulty Motor on Freezer

Replaced faulty motor on Freezer with a new one and also charged unit with 2.7 lbs. of r404a to make repairs on 9/13/24 in Dallas Texas. Near North Westmoreland Road Dallas, Texas 75211 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]