Condensate Pump Wouldn’t Turn Off
Condensate pump wouldn’t turn off. So I turned on breaker and heard it. I ran water to it and then blew it out with nitrogen. All the gunk came out that was holding the condensate pump float switch up and causing it to run. When done I turned ice machine on and saw the pump […]
Removed and Replaced Liquid Header
Removed and replaced liquid header. I noticed a lot of black oily sludge and flushed the primary circuit with RX professional heavy-duty system cleaner for burnouts and greasy oily buildup on 1/26/24 in Dallas Texas. Near Lyndon B Johnson Fwy Dallas, Texas 75251 Check out the Areas We Serve and jobs we are doing by […]
Emptied Ice Machines and Cleaned
Emptied ice machines and cleaned. Performed Preventative Maintenance and cleaned up on 1/25/24 in Plano Texas. Near W Park Blvd Plano, Texas 75093 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
Found a Leak on the Service Port Suction Line
Found a leak on the service port suction line. I repaired leak and got pressure to where it needed to be . Verified temp drop on 1/20/24 in Lake Dallas Texas. Near Main St Lake Dallas, Texas 75065 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
The High Side Pressure was Struggling to get over 100psi
The high side pressure was struggling to get over 100psi so I attached the second condenser fan to the FCS to allow the unit to build some high side pressure. I then set the superheat and the unit made temp without any issue on 1/19/24 in Richardson Texas. Near S Central Expy Richardson, Texas 75080 […]
Replaced Filters that were Extremely Dirty
Replaced filters that were extremely dirty and restricting airflow on 1/18/24 in Dallas Texas. Near S Lancaster Rd Dallas, Texas 75216 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
Unit Was Getting Power but Was Not Switching On
Unit was getting power but was not switching on. I replaced the clock and confirmed the unit was functioning properly on 1/17/24 in Dallas Texas. Near Greenville Ave Dallas, Texas 75206 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
Deiced the Coil and Pan
Deiced the coil and pan and all around the electrical. Raised the coil and removed the old heater. Then I placed and positioned new heater and locked in place then reassembled the coil back in place and turned unit on. Verified heater worked. Also, I silicone a piece of drain pipe to further ensure no […]
Standard Salad and Go Start Up on 1.9.24
Standard salad and go start up on 1.9.24. Had to add 2# of 404a on top of customer provided amount in Flower Mound Texas. Near Flower Mound Rd. Flower Mound, Texas 75028 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
There were 5 Holes from the Cap Tube Rubbing the U-bend
There were 5 holes from the cap tube rubbing the u-bend. I patched it with solder and pulled a vacuum on 1/3/24 in Dallas Texas. Near N Beckley Ave Dallas, Texas 75203 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]