Penetrative Maintenance done on All Equipment
Penetrative Maintenance done on all equipment on 9/14/2023. All of the small units were clean and at temp with. No seen issues. The WIC evaporator coil is a little dirty but nothing to be too concerned about this trip out. The WIC condenser had a clean coil and was running very well. The WIF evaporator […]
I Could Actually Feel The Leak
I could actually feel the leak as I peeled back the plastic covering. I replaced the entire section of pipe with 1/4 soft copper tubing and added service port. I also replaced the spin copper drier. I pulled a deep vacuum and recharged the system with fresh r290. System can be returned to service after […]
Washed Condenser and Straightened Coil Fins
Washed condenser and straightened coil fins on 9/12/2023. Also tightened vent a hood belt and lubed bearings in Carrollton Texas. Near Old Denton Road Carrollton, Texas 75007 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
Checked Two Glass Freezer and Controller
Checked two glass freezer and controller tends to fluctuate temp and client asked if could set to 4°F so I replaced Ranco controller with adjustable temp mechanical controller in Farmers Branch Texas. Near Medical Pkwy Farmers Branch, Texas 75234 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
Found the water valve faulty
Found the water valve faulty and the water pump faulty on 8/31/2023 and I replaced both parts and verified harvest of ice three times in Addison Texas. Near Addison Cir Addison, Texas 75001 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
Prep Cooler Leaking at Schrader Core
On 8/28/2023 8/30/2023 1. True prep cooler leaking at Schrader core replaced it and added one pound 2. Second unit also had leak fixed it by brazing and then added one lb. r134a and saw temp drop in Plano Texas. Near W Spring Creek Pkwy Plano, Texas 75023 Check out the Areas We Serve and […]
Leak Detector Went Off as Soon as I Stepped In The Room
On 8/28/2023 I started leak checking the evap and the leak detector went off as soon as I stepped in the room. I opened the main door as well as a couple glass doors to let it air out. I started another leak detection and found that there was a core cap missing and some […]
Unit Off on High Pressure
On 8/18/2023 Unit off on high pressure washed unit condenser coil and left unit in operation in Plano Texas. Near East 15th Street Plano, Texas 75074 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
The Condenser Coils were Very Dirty
On 8/15/2023 Changed filters and ran through a typical pm check. Found that the condenser coils were very dirty so I pulled a hose to the roof and cleaned them with chemical coil cleaner in FRISCO Texas. Near W Stonebrook Pkwy FRISCO, Texas 75034 Check out the Areas We Serve and jobs we are doing […]
Checked Hoshizaki Ice Machine
On 8/10/2023 Checked Hoshizaki ice machine and found condenser coil dirty soni cleaned it and also float switch dirty soni cleaned it as well then verified three harvests in Dallas Texas. Near Lyndon B Johnson Fwy Dallas Texas 75251 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]