Pro Refrigeration NT LLC

4th Floor Machine was in a Menu Screen

4th floor machine was in a menu screen when I arrived. I backed it out to the main menu and the unit was in off mode. I turned it on and watched it make ice three times in 12 minute cycles on 11/3/23 in Lewisville Texas. Near State Hwy 121 Lewisville, Texas 75067 Check out […]

Checked Ice Machine for Cleanliness and Proper Operation

Checked ice machine for cleanliness and proper operation for standard preventative maintenance on 10/30/23 in Dallas Texas. Near Park Ln Dallas, Texas 75231 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Fan Bracket Had Cracked

Fan Bracket had cracked causing the fan to drop on 10/27/23. Removed old fan base bracket and replaced then verified correct size and put cover back on in Rowlett Texas. Near Lakeview Pkwy Rowlett, Texas 75088 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Heard Compressor Try to Start

Heard compressor try to start but it wouldn’t I went and picked up overload device and installed and compressor started up verified temp drop on 10/24/23 in Flower Mound Texas. Near Cross Timbers Rd Flower Mound, Texas 75028 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Found Leak at the High-Pressure Control

Found leak at the high-pressure control connection. I tightened the fitting and confirmed there were no other leaks. I added 4# of 404a. I noticed that the second fan was not going off on the fan control setting causing the pressure to drop very low in the cooler weather. I checked the wiring and found […]

The Rail Thermostat Had Not Met its Set Point

The rail thermostat had not met its set point. I changed the thermostat and watched the temp drop to setpoint without issue on 10/20/23 in Plano Texas. Near West Plano Parkway Plano, Texas 75093 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Basic Start up at Salad and Go

Basic start up at salad and go on 10/19/23. One evaporator fan came unplugged during delivery. Plugged it in without any issue in Garland Texas. Near North Garland Avenue Garland, Texas 75040 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Install Customer Provided Ice Machine

Install customer provided ice machine and test functionality on 10/18/23 in Dallas Texas. Near Stults Road Dallas, Texas 75243 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]

Ground Wire on the Compressor Came Loose

Ground wire on the compressor came loose and was shorting against the common. I installed the wire correctly and start the unit up. It was low on Freon so I topped it off and confirmed several cycles on 10/17/2023 in Plano Texas. Near W Plano Pkwy Plano, Texas 75093 Check out the Areas We Serve […]

Coil Iced and Evaporator Motors Not Working

Coil iced and Evaporator motors not working, installed two new motors and verified proper function. Watched the temp fall into the twenties and steadily dropping on 10/16/2023 in Dallas Texas. Near Grader Street Dallas, Texas 75238 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]