Condenser Switch had a Burnt Wire and Bad Connector
On 3/27/2023 When I arrived the unit was unplugged. After plugging it back in I was getting no power to the unit at all. I checked the breakers which were fine. I tested the current at the outlet which was also fine. I started tracing the wiring and found at the condenser switch had a […]
Installed New Condenser on Roof
On 3/22/2023 Installed new Condenser on roof. Piped in both condensers and made roof penetrations. Completed piping both units. Insulated all the suction lines and picked up parts for copper drain since I was unable to use PVC on the cooler due to space in Fort Worth Texas. Near North Tarrant Parkway Fort Worth, Texas […]
Cleaned off Ice Thickness Probe
On 3/14/2023 Checked Scotsman iceman. Board was showing code 8, meaning a short freeze cycle. Reset board. Let the ice machine run through a cycle. Found that the ice machine took a while to drop the ice sheet down. Inspected evaporator coil found scale build up and found that water was not dispersing on the […]
Completed the Condenser Install at Salad and Go
On 3/13/2023 completed the condenser install at salad and go. Make roof penetration, set condenser, couple in the existing piping and tie into condenser, place nitrogen charge on system in Plano Texas. Near Midway Road Plano, Texas 75093 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]
Installed New Compressor and Filter Drier
On 3/10/2023 Recovered freon from system. Removed old compressor. Installed new compressor and filter drier. Pulled vacuum charge on system. Replaced contactor. Charged unit with the freon I recovered. Added 7 lbs of freon to system. Found leak on suction line core. Replaced core. Box will take all night to pull down. May have to […]
Found Dust on Fan Guard
On 3/9/2023 Checked both coolers. On the 2-door cooler. Found dust on fan guard. Removed fan guard and cleaned it off. On the single door cooler. Found brown substance on fan and fan guard. Removed those and cleaned off. Blew drain out on 2 door cooler in Rockwall Texas. Near Sunset Ridge Drive Rockwall, Texas […]
Ice Thickness Probe Needed to be Adjusted
On 3/6/2023 Checked ice machine. Found that ice thickness probe needed to be adjusted. Ice machine was going into a long freeze mode causing ice not to drop every once in a while in Rowlett Texas. Near Lakeview Pkwy Rowlett, Texas 75088 Check out the Areas We Serve and jobs we are doing by clicking […]
Installed New Curtain Switch
Menu Blood Plasma Freezers Chiller Repairs Energy Management Freezers Glycol Chiller Hot Side Repair HVAC Installs HVAC Repairs Ice Machine Ice Machine Rentals Maintenance Swift Sensors Truck Refrigeration Ice Merchandiser Walk-In Cooler Wine Coolers Installed New Curtain Switch On 3/3/2023 Ice machine was off on bin full code. Bin was empty so I tested the […]
Water Pump had a Hairline Crack
On 3/1/2023 Checked ice machine. Found that ice machine was making thin ice. Found that the water pump had a hairline crack that was spitting water out causing the freeze process to starve for water. Picked up new water pump and returned back to install. After installing checked operation. Ice cubes came out normal size. […]
Quote to Replace Door
On 2/28/2023 Checked broken cooler door for quote to replace door. Will submit quote before ordering. Also need to order 5 torque rods and masters in Lewisville Texas. Near Hebron Pkwy Lewisville, Texas 75057 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerationone.com/areas-we-serve/ [spacer]