Startup and Completion of New Refrigeration System
On 1/30/2023 install boxes, equipment, door, refrigerant piping, drain piping, start up and completion of new refrigeration system (GC to receive equipment) in Plano Texas. Near Democracy Dr Plano, Texas 75024 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer]
Installed New Ice Machine
On 1/24/2023 Removed old ice machine and installed new ice machine. Used 3/4 coupling to tie in drain. Checked operation of new ice machine in Balch Springs Texas. Near Seagoville Rd Balch Springs, Texas 75180 Check out the Areas We Serve and jobs we are doing by clicking https://dallas.prorefrigerate.com/areas-we-serve/ [spacer]
Checked Reach in Cooler Door Switch Had Popped Up
On 1/17/2023 Checked reach in cooler. Found that the door switch popped up causing the fan not to come on. The result of this caused the coil to ice up. Fixed door fan switch. Unit will have to stay off overnight to thaw out in Mesquite Texas. Near South Bryan-Belt Line Road Mesquite, Texas 75149 […]
Replaced Both Start Relay and Start Capacitor
On 1/9/2023 Checked beverage cooler. Found that the start relay was burned up. Also found that the start capacitor went bad. Replaced both start relay and start capacitor. Also fixed all burned wires. Checked operation. Compressor amping at 8.8 amps in Dallas Texas. Near GREENVILLE AVE Unit 205 Dallas, Texas 75206 Check out the Areas […]
Condenser Coil was Plugged With Dust
On 1/6/2023 Checked break room refrigerator. Found that compressor was hot to the touch due to it being off on internal overload. This happened because the condenser coil was plugged with dust. Brushed dust off the coil and blew it out with nitrogen. Put a bag of ice on top of the compressor to cool […]
Replaced Reach in Cooler Starting Components
On 11/4/2023 Checked reach in cooler. Found that condenser fan motor running but the compressor was not. Checked compression with mega ohm meter, compressor is good but it’s on its way out. Replaced reach in cooler starting components. Checked operation. Compressor came on and is cooling down the box in Frisco Texas. Near Frisco St […]
Found that Everything in the Inside Fell Apart like the Unit was Roughly Handled
On 1/3/2022 Checked reach in freezer. Found that everything in the inside fell apart like the unit was roughly handled. Mounted the evaporator coil back up to case ceiling. Fixed sensor on coil due to the wiring breaking. Once everything was back together tested operation. Found that one motor was bad and 2 fan blades […]
Install New Control Board and Bin Switch
On 12/02/2022 Install new control board and bin switch. Recover refrigerant, power down unit, remove compressor and filter, installed new compressor and filter, pull vacuum on system, charge system with refrigerant. Power up unit and confirm proper function in Dallas Texas. Near Adelia rd. Dallas, Texas 75238 Check out the Areas We Serve and jobs […]